Strata IP-CTX time and date update

Program Number: 902
Prerequisite Program: None
Reference: None
Access Sequence: Login to programming mode from your telephone button pad:
Hold *#*#1*2*3*
At the PASSWORD= prompt, enter your password and press Hold
At the PROG= prompt enter 902 and press Hold

FB Name
FB
Summary Value LCD Prompt
Date

01

Enter current system date in this field

yymmdd format
yy = year
mm = month
dd = day

DATE=
Time
02
Enter the current time in this field hhmmss format
hh = hour
mm = minute
ss = second
TIME=
  1. Press FB01 to enter current Strata IP-CTX date. See table above for format
  2. Press Hold to program
  3. Press FB02 to enter current Strata IP-CTX time. See table above for format
  4. Press Hold to program
  5. Press Hold to submit, then # # Hold to return to the PROG= prompt
  6. Enter another program number to continue programming or press # # Hold again to exit programming mode